采用瞬态实验方法研究了3种排列角度(15°、30°和45°)下的扰流孔波纹板蓄热元件的传热性能,并比较了等效泵功下的Nu/Nuo*值.结果表明:与未添加扰流孔的波纹板蓄热元件相比,3种排列角度下的带扰流孔的波纹板蓄热元件的平均Nu分别提高了17.1%、24.8%和34.9%;3种情况下的平均阻力因数f分别提高了24.7%、33.1%和38.4%;与排列角度为30°和15°相比,45°时的Nu/Nuo*分别提高了53.3%和67.8%,表明扰流孔排列角度为45°时,波纹板蓄热元件具有最佳性能.
Abstract
Transient test method was used to study the heat transfer performance of corrugated plate with staggered perforations in different arrangements (15°, 30° and 45°), and to compare the value of Nu/Nuo* at equal pumping power. Results show that compared with corrugated plates without perforations, the average Nu of the plate with staggered perforations in above three arrangements is increased by 17.1%, 24.8% and 34.9% respectively, with an increase of friction factor f by 24.7%, 33.1% and 38.4% accordingly. Compared with the arrangements of 15° and 30°, the value of Nu/Nuo* in the case of 45° is correspondingly increased by 53.3% and 67.8%, indicating that the heat transfer performance of corrugated plate reaches the maximum in the arrangement of 45°.
关键词
扰流孔 /
波纹板蓄热元件 /
强化传热 /
传热性能 /
实验研究
{{custom_keyword}} /
Key words
perforation /
corrugated plate heat transfer element /
heat transfer enhancement /
heat transfer performance /
experimental study
{{custom_keyword}} /
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] 林宗虎,徐通模.实用锅炉手册[M].北京:化学工业出版社,2009.
[2] 国家电力公司电力机械局,中国华电工程(集团)公司,中电联标准化中心.电站锅炉空气预热器[M].北京:中国电力出版社,2002.
[3] SAHIN B,DEMIR A. Performance analysis of a heat exchanger having perforated square fins[J].Applied Thermal Engineering,2008,28(5/6):621-632.
[4] SAHIN B,DEMIR A. Thermal performance analysis and optimum design parameters of heat exchanger having perforated pin fins[J].Energy Conversion and Management,2008,49(6):1684-1695.
[5] KARABACAK R,YAKAR G. Forced convection heat transfer and pressure drop for a horizontal cylinder with vertically attached imperforate and perforated circular fins[J].Energy Conversion and Management,2011,52(8):2785-2793.
[6] ZHANG Lei,CHE Defu. Influence of corrugation profile on the thermal-hydraulic performance of cross-corrugated plates[J].Numerical Heat Transfer,Part A:Applications:An International Journal of Computation and Methodology,2011,59(4):267-296.
[7] ZHANG Lizhi. Turbulent three-dimensional air flow and heat transfer in a cross-corrugated triangular duct[J].Journal of Heat Transfer,2005,127(10):1151-1158.
[8] JAIN S,JOSHI A,BANSAL P K. A new approach to numerical simulation of small sized plate heat exchangers with chevron plates[J].Journal of Heat Transfer,2006,129(3):291-297.
[9] WANG Qiuwang,ZHANG Dongjie,XIE Gongnan. Experimental study and genetic-algorithm-based correlation on pressure drop and heat transfer performances of a cross-corrugated primary surface heat exchanger[J].Journal of Heat Transfer,2009,131(6):061802.
[10] SHEER T J,DEKLERK G B,JAWUREK H H,et al. A versatile computer simulation model for rotary regenerative heat exchangers[J].Heat Transfer Engineering,2006,27(5):68-79.
[11] CHANG Z C,HUNG M S, DING P P,et al. Experimental evaluation of thermal performance of Gifford-McMahon regenerator using an improved single-blow model with radial conduction[J].International Journal of Heat and Mass Transfer,1999,42(3):405-413.
[12] SHAJI K,SARIT K D. The effect of flow maldistribution on the evaluation of axial dispersion and thermal performance during the single-blow testing of plate heat exchangers[J].International Journal of Heat and Mass Transfer,2010,53(7):1591-1602.
[13] ZHANG Lei,CHE Defu. An experimental and numerical investigation on the thermal-hydraulic performance of double notched plate[J].Journal of Heat Transfer,2012,134(9):091802.
[14] 黄风良,孙志坚,李鹏程,等.带扰流孔波纹板的传热和阻力特性[J]. 浙江大学学报(工学版),2015,49(7):1242-1248. HUANG Fengliang,SUN Zhijian,LI Pengcheng,et al. Heat transfer and resistance characteristics of corrugated plate with spoiler holes[J].Journal of Zhejiang University(Engineering Science),2015, 49(7):1242-1248.
[15] 陶文铨.数值传热学[M].西安:西安交通大学出版社,2010.
[16] 张国立,杨立,孙丰瑞,等.管内插入网状肋强化换热的数值研究[J]. 动力工程学报,2010,30(2):123-127. ZHANG Guoli,YANG Li,SUN Fengrui,et al. Numerical study of heat transfer enhancement by inserting reticulated ribs in pipes[J].Journal of Chinese Society of Power Engineering,2010,30(2):123-127.
[17] KARWA R, MAHESHWARI B K, KARWA N. Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles[J].International Communications in Heat and Mass Transfer,2005,32(1/2):275-284.
{{custom_fnGroup.title_cn}}
脚注
{{custom_fn.content}}
基金
金华市科学技术研究计划重点资助项目(20131031)
{{custom_fund}}