扰流孔强化波纹板蓄热元件传热性能的实验研究

李鹏程, 孙志坚, 黄浩, 汤舟, 胡亚才

PDF(593 KB)
动力工程学报 ›› 2016, Vol. 36 ›› Issue (7) : 530-534.
辅机技术

扰流孔强化波纹板蓄热元件传热性能的实验研究

  • 李鹏程, 孙志坚, 黄浩, 汤舟, 胡亚才
作者信息 +

Experimental Study on Heat Transfer Enhancement of Corrugated Plate by Staggered Perforations

  • LI Pengcheng, SUN Zhijian, HUANG Hao, TANG Zhou, HU Yacai
Author information +
History +

摘要

采用瞬态实验方法研究了3种排列角度(15°、30°和45°)下的扰流孔波纹板蓄热元件的传热性能,并比较了等效泵功下的Nu/Nuo*值.结果表明:与未添加扰流孔的波纹板蓄热元件相比,3种排列角度下的带扰流孔的波纹板蓄热元件的平均Nu分别提高了17.1%、24.8%和34.9%;3种情况下的平均阻力因数f分别提高了24.7%、33.1%和38.4%;与排列角度为30°和15°相比,45°时的Nu/Nuo*分别提高了53.3%和67.8%,表明扰流孔排列角度为45°时,波纹板蓄热元件具有最佳性能.

Abstract

Transient test method was used to study the heat transfer performance of corrugated plate with staggered perforations in different arrangements (15°, 30° and 45°), and to compare the value of Nu/Nuo* at equal pumping power. Results show that compared with corrugated plates without perforations, the average Nu of the plate with staggered perforations in above three arrangements is increased by 17.1%, 24.8% and 34.9% respectively, with an increase of friction factor f by 24.7%, 33.1% and 38.4% accordingly. Compared with the arrangements of 15° and 30°, the value of Nu/Nuo* in the case of 45° is correspondingly increased by 53.3% and 67.8%, indicating that the heat transfer performance of corrugated plate reaches the maximum in the arrangement of 45°.

关键词

扰流孔 / 波纹板蓄热元件 / 强化传热 / 传热性能 / 实验研究

Key words

perforation / corrugated plate heat transfer element / heat transfer enhancement / heat transfer performance / experimental study

引用本文

导出引用
李鹏程, 孙志坚, 黄浩, 汤舟, 胡亚才. 扰流孔强化波纹板蓄热元件传热性能的实验研究. 动力工程学报. 2016, 36(7): 530-534
LI Pengcheng, SUN Zhijian, HUANG Hao, TANG Zhou, HU Yacai. Experimental Study on Heat Transfer Enhancement of Corrugated Plate by Staggered Perforations. Journal of Chinese Society of Power Engineering. 2016, 36(7): 530-534

参考文献

[1] 林宗虎,徐通模.实用锅炉手册[M].北京:化学工业出版社,2009.
[2] 国家电力公司电力机械局,中国华电工程(集团)公司,中电联标准化中心.电站锅炉空气预热器[M].北京:中国电力出版社,2002.
[3] SAHIN B,DEMIR A. Performance analysis of a heat exchanger having perforated square fins[J].Applied Thermal Engineering,2008,28(5/6):621-632.
[4] SAHIN B,DEMIR A. Thermal performance analysis and optimum design parameters of heat exchanger having perforated pin fins[J].Energy Conversion and Management,2008,49(6):1684-1695.
[5] KARABACAK R,YAKAR G. Forced convection heat transfer and pressure drop for a horizontal cylinder with vertically attached imperforate and perforated circular fins[J].Energy Conversion and Management,2011,52(8):2785-2793.
[6] ZHANG Lei,CHE Defu. Influence of corrugation profile on the thermal-hydraulic performance of cross-corrugated plates[J].Numerical Heat Transfer,Part A:Applications:An International Journal of Computation and Methodology,2011,59(4):267-296.
[7] ZHANG Lizhi. Turbulent three-dimensional air flow and heat transfer in a cross-corrugated triangular duct[J].Journal of Heat Transfer,2005,127(10):1151-1158.
[8] JAIN S,JOSHI A,BANSAL P K. A new approach to numerical simulation of small sized plate heat exchangers with chevron plates[J].Journal of Heat Transfer,2006,129(3):291-297.
[9] WANG Qiuwang,ZHANG Dongjie,XIE Gongnan. Experimental study and genetic-algorithm-based correlation on pressure drop and heat transfer performances of a cross-corrugated primary surface heat exchanger[J].Journal of Heat Transfer,2009,131(6):061802.
[10] SHEER T J,DEKLERK G B,JAWUREK H H,et al. A versatile computer simulation model for rotary regenerative heat exchangers[J].Heat Transfer Engineering,2006,27(5):68-79.
[11] CHANG Z C,HUNG M S, DING P P,et al. Experimental evaluation of thermal performance of Gifford-McMahon regenerator using an improved single-blow model with radial conduction[J].International Journal of Heat and Mass Transfer,1999,42(3):405-413.
[12] SHAJI K,SARIT K D. The effect of flow maldistribution on the evaluation of axial dispersion and thermal performance during the single-blow testing of plate heat exchangers[J].International Journal of Heat and Mass Transfer,2010,53(7):1591-1602.
[13] ZHANG Lei,CHE Defu. An experimental and numerical investigation on the thermal-hydraulic performance of double notched plate[J].Journal of Heat Transfer,2012,134(9):091802.
[14] 黄风良,孙志坚,李鹏程,等.带扰流孔波纹板的传热和阻力特性[J]. 浙江大学学报(工学版),2015,49(7):1242-1248. HUANG Fengliang,SUN Zhijian,LI Pengcheng,et al. Heat transfer and resistance characteristics of corrugated plate with spoiler holes[J].Journal of Zhejiang University(Engineering Science),2015, 49(7):1242-1248.
[15] 陶文铨.数值传热学[M].西安:西安交通大学出版社,2010.
[16] 张国立,杨立,孙丰瑞,等.管内插入网状肋强化换热的数值研究[J]. 动力工程学报,2010,30(2):123-127. ZHANG Guoli,YANG Li,SUN Fengrui,et al. Numerical study of heat transfer enhancement by inserting reticulated ribs in pipes[J].Journal of Chinese Society of Power Engineering,2010,30(2):123-127.
[17] KARWA R, MAHESHWARI B K, KARWA N. Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles[J].International Communications in Heat and Mass Transfer,2005,32(1/2):275-284.

基金

金华市科学技术研究计划重点资助项目(20131031)
PDF(593 KB)

Accesses

Citation

Detail

段落导航
相关文章

/