    CAO Ting, ZHENG Canghai, LI Yongli, WANG Yiwei, QIN Ning, BAI Zhanguo, LIU Jie, ZHANG Lei, DENG Lei. Analysis of Hydrodynamic Force and Wall Temperature Characteristics of a Supercritical Boiler Under Low LoadsJ. Journal of Chinese Society of Power Engineering, 2024, 44(11): 1680-1688,1711. DOI: 10.19805/j.cnki.jcspe.2024.230581
    Citation: CAO Ting, ZHENG Canghai, LI Yongli, WANG Yiwei, QIN Ning, BAI Zhanguo, LIU Jie, ZHANG Lei, DENG Lei. Analysis of Hydrodynamic Force and Wall Temperature Characteristics of a Supercritical Boiler Under Low LoadsJ. Journal of Chinese Society of Power Engineering, 2024, 44(11): 1680-1688,1711. DOI: 10.19805/j.cnki.jcspe.2024.230581

    Analysis of Hydrodynamic Force and Wall Temperature Characteristics of a Supercritical Boiler Under Low Loads

    • To explore the deep peak shaving capacity of coal-fired boilers, the hydrodynamic force and wall temperature characteristics of the water-cooled wall of a supercritical 630 MW boiler were studied. Mathematical models of the hydrodynamic force and wall temperature characteristics were established, and water-cooled wall pressure drop, flow distribution, outlet working substance temperature and wall temperature distribution along the furnace height between 20% and 30% boiler maximum continuous rating (BMCR) loads were analyzed. Results show that, the helical tube sections of the water-cooled wall exhibit small thermal deviation and uniform heat load distribution under 20% and 30% BMCR loads. The outlet steam temperature deviation of the vertical tube sections of the water-cooled wall is large, and the over-temperature is more likely to occur in this area. Under 30% BMCR load, the boiler could operate safely in dry state condition. Under 28.8% BMCR load, the inlet water temperature of the water-cooled wall is 280.0 ℃, and the maximum wall temperature of the water-cooled wall in dry state condition exceeds 450.0 ℃. Under 27.3% BMCR load, the maximum wall temperature of the water-cooled wall in dry state condition exceeds 500.0 ℃, and the boiler should operate in wet state condition or the wall temperature should be reduced by adjusting the inlet water temperature.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return