    燃煤机组SCR脱硝系统的建模与控制

    Modeling and control methods for the SCR denitrification system of coal-fired units

    • 摘要: 针对NOx在线监测系统存在测量滞后,若将SCR入口NOx浓度的监测值作为控制系统的喷氨量前馈会导致喷氨量控制滞后,从而导致氨逃逸或NOx排放超标的问题,提出基于改进粒子群(improved particle swarm optimization,IPSO)优化时间感知动态因果图卷积网络(temporally aware dynamic causal graph convolutional network,TDCGCN)的SCR入口NOx浓度预测模型,并基于该预测模型设计SCR脱硝系统控制策略。首先,在传统PSO算法的基础上引入模拟退火算法改善其易陷入局部最优的局限,在此基础上构建基于IPSO算法优化TDCGCN的入口NOx浓度预测模型;其次,将入口NOx浓度预测值作为喷氨量前馈加入控制回路中,建立基于入口NOx浓度预测的PID+前馈脱硝控制结构;最后,在某1000MW燃煤机组的实时运行数据下进行仿真验证。实验结果表明:TDCGCN网络通过考虑SCR脱硝系统的时序以及单向因果特性,提升了模型的预测效果;所提控制策略可以提前调节喷氨量,提升了出口NOx浓度的脱硝效率和稳定性。

       

      Abstract: To address the measurement lag inherent in NOx online monitoring systems—where using the monitored selective catalytic reduction (SCR) inlet NOx concentration as the feedforward signal for ammonia injection leads to delayed injection control, which may cause ammonia slip or excessive NOx emissions—this paper proposes an SCR inlet NOx concentration prediction model based on a temporally aware dynamic causal graph convolutional network (TDCGCN) optimized by an improved particle swarm optimization (IPSO) algorithm, and further designs an SCR denitrification control strategy based on the prediction model. First, a simulated annealing algorithm is introduced into the conventional PSO to overcome its limitation of being prone to local optima, forming the IPSO algorithm. On this basis, the inlet NOx concentration prediction model is constructed using TDCGCN optimized by the IPSO algorithm. Second, the predicted inlet NOx concentration is incorporated as the ammonia injection feedforward signal into the control loop, establishing a PID plus feedforward denitrification control structure based on inlet NOx concentration prediction. Finally, simulation verification is carried out using real-time operational data from a 1000 MW coal-fired unit. The experimental results demonstrate that the TDCGCN network improves prediction performance by capturing the temporal and unidirectional causal characteristics of the SCR denitrification system, and that the proposed control strategy enables proactive adjustment of the ammonia injection rate, thereby enhancing the denitrification efficiency and stability of the outlet NOx concentration.

       

    /

    返回文章
    返回