高级检索

    含储热系统的CCUS燃煤电站性能与经济性研究

    Research on Performance and Economics of CCUS Coal-fired Power Plants with Thermal Energy Storage Systems

    • 摘要: 针对燃煤电站深度调峰与低碳化改造需求,构建了熔融盐储热辅助的碳捕集、利用与封存(CCUS)燃煤发电系统,采用EBSILON和ASPEN PLUS软件分别建立储热系统与碳捕集系统模型,对630 MW机组进行全流程仿真。通过经济性评估研究了储热系统对调峰能力的提升机制及CCUS系统对碳排放的影响规律。结果表明:储热系统采用双罐熔融盐方案,设计储热容量为875 MW·h,储热效率达95%,储热罐容积为6 730 m3,单位造价为175元/(kW·h);在各工况下,CCUS系统的二氧化碳捕集率始终保持在90%,年减排量达165.46万t;改造后机组调峰深度从40%降至0%,调峰容量增加180.1 MW,度电成本由0.374 8元/(kW·h)变为0.365 3元/(kW·h);项目总投资为23.74亿元,当碳交易价格为98元/t时,净现值为5.73亿元,投资回收期约为19 a;碳价每上涨10元/t,度电成本下降0.002 7元/(kW·h),调峰补偿价格每上涨50元/(MW·h),度电成本下降0.004元/(kW·h)。本研究为燃煤机组灵活性改造与低碳化协同发展提供了技术路径与经济评估依据。

       

      Abstract: To address the demands for deep peak shaving and low-carbon retrofitting of coal-fired power plants, a molten salt thermal energy storage-assisted carbon capture, utilization and storage (CCUS) coal-fired power generation system was proposed. Models of the thermal energy storage system and carbon capture system were developed using EBSILON and ASPEN PLUS software, respectively, enabling full-process simulation of a 630 MW unit. The economic was evaluated to study the mechanisms of thermal storage systems in enhancing peak-shaving capabilities and the impact of CCUS systems on carbon emissions. Results show that the thermal energy storage system adopts a dual-tank molten salt configuration with a designed storage capacity of 875 MW·h, achieving a thermal efficiency of 95%. The storage tank volume is 6 730 m3, with a unit cost of 175 yuan/(kW·h). Under various operating conditions, the CO2 capture rate of the CCUS system remains consistently at 90%, with an annual emission reduction of 1.654 6 million tons. After retrofitting, the unit's peak-shaving depth decreases from 40% to 0%, while the peak-shaving capacity increases by 180.1 MW, and the levelized cost of electricity (LCOE) changes from 0.374 8 yuan/(kW·h) to 0.365 3 yuan/(kW·h). The total project investment amounts to 2.374 billion yuan. Under the carbon trading price of 98 yuan/t, the net present value reaches 573 million yuan, with a payback period of approximately 19 years. Sensitivity analysis reveals that for every 10 yuan/t increase in carbon price, the LCOE decreases by 0.002 7 yuan/(kW·h), and for every 50 yuan/(MW·h) increase in peak-shaving compensation price, the LCOE decreases by 0.004 yuan/(kW·h). This study provides a technical pathway and economic assessment framework for the synergistic development of flexibility retrofitting and low-carbon transformation in coal-fired power units.

       

    /

    返回文章
    返回